03 November 2025
The most common building inspection fails
Main reasons for individual inspection fails in the last year in Auckland (residential and commercial).
Framing (32%)
- Wall bracing connections not installed correctly or missing
- Steel beams and fixings non-compliant
- Timber beams and fixings non-compliant
- Top and bottom plate sizes and fixings incorrect
- Wall framing point load stud locations/fixings incorrect
Cladding (25%)
- Cladding junction details not installed correctly
- Cladding fixings incorrect
- Cladding integrity or damage
- Roof flashings incomplete
- Non-compliance cladding clearances (to ground, roofs, other materials)
Cavity wrap (30%)
- Flashings at junctions installed correctly
- Head, sill, jamb flashings or support bars not installed correctly
- Building wrap and restraint too loose, inadequate laps or holes
- Apron flashing support, size or end detail (e.g. kickout) non-compliant
- Pipe penetrations not installed correctly (falls and tape flashings)
Foundations (17%)
- Piles footing sizes incorrect
- Piles sizes and heights incorrect
- Set out on site not as per plan
- Drain bridging non-compliant
- Strip foundation width, depth or layout not as per plan
- Strip foundations reinforcing size, grade, laps or bends non-compliant
- Surface water control non-compliant
- Silt and erosion control not installed
- Insufficient concrete cover to foundation reinforcing
- Inadequate ground or soil conditions
Drainage (14%)
-
Drainage as-built plan not onsite
- Storm water not as per design
- Drain test failed
- Rain water tank type, location and installation not as per design
- Pipework trench width/depth or bedding incorrect
Pre-line (36%)
- Timber framing moisture content too high
- Joinery not installed correctly (includes air seals)
- Corner steel angles for tiles not installed
- Balustrade or barrier framing not structurally adequate or too low
- Insulation installation non-compliant
Slab (13%)
- Raft Slab size, layout, thickness or shape incorrect
- Inadequate reinforcing concrete cover
- Insufficient mesh and reinforcing size or laps
- Inadequate under-slab hardfill, blinding or DPM
- Hardfill or blinding not runout past slab edge enough
Final inspection (37%)
- Smoke alarms not installed or interconnected
- Cladding penetrations and junctions not adequately weathertight
- Inadequate clearances between cladding to finished ground level
- Non-compliant entry stairs, landing, handrail or barriers
- Drainage: ORG / gully trap installed incorrectly
- Flashings incomplete or not weathertight
- Window/door joinery not weathertight
- Hot water temperature too hot
- Hot water cylinder installation non-compliant
- Inadequate clearances between finished floor level and ground level